Worksafe Victoria requires Concrete Placing Equipment (Concrete Pumps) to be annually inspected by a qualified engineer (competent person). According to the Australian Standard AS 2550.15-1994 Cranes - Safe use - Concrete placing equipment a concrete pump needs a
Learn MoreThe exposure standard for respirable crystalline silica dust is 0.05 mg/m3 as a time-weighted average (TWA) airborne concentration over 8 hours. An 8-hour TWA exposure standard is the average airborne concentration of a particular substance permitted over an 8-hour working day and 5-day working week. WorkSafe Victoria recommends that employers ...
Learn MoreMost recently a male 24 was struck and seriously injured while cleaning out the concrete pumping equipment used in a concrete pour on a rural property in northeast Victoria. He later died in hospital. Control measures. WorkSafe expects that when cleaning out concrete pumping equipment the following safety precautions are followed:
Learn MoreWorksafe Victoria Concrete Pumping Industry Standard (extract): 7.2 ANNUAL INSPECTIONS 7.2.1 General All concrete pumping equipment should be subject to an annual inspection by a competent person at intervals not exceeding 365 days.
Learn MoreExposure standard. Safe Work Australia publishes exposure standards for airborne contaminants in the workplace. The exposure standard for crystalline silica dust (listed under Quartz (respirable dust)) is 0.05mg/m3 as a TWA (time-weighted average) airborne concentration over 8 hours. An 8-hour time-weighted average exposure standard is the ...
Learn MoreIndustry standard: Concrete pumping Precast and tilt-up concrete construction Was the information on this page helpful? Yes No ... WorkSafe Victoria acknowledges Aboriginal and Torres Strait Islander people as the Traditional Custodians of the land and acknowledges and
Learn MoreConsultation with WorkSafe Victoria ensured overall compatibility with occupational health and safety legislation and technical alignment with Australian Standards. The Foundations for Safety full committee endorsed this document as an Industry Standard in October 2003. ... INDUSTRY STANDARD FOR CONCRETE PUMPING 45 APPENDIX A - REFERENCE ...
Learn MoreConcrete pumping : industry standard WorkSafe Melbourne 2004. Australian/Harvard Citation. WorkSafe Victoria. 2004 Concrete pumping : industry standard WorkSafe Melbourne. Wikipedia Citation. Please see Wikipedia's template documentation for further citation fields that may be required.
Learn MoreThis document explains the industry standards to operate maintain and dispose of concrete pumping equipment. Use this document to establish and maintain a safe working environment when using concrete pumping. It explains: how occupational health and safety (OHS) duties apply to the concrete pumping industry including how to manage hazards.
Learn MoreUse this document to plan safety when designing manufacturing transporting and building precast concrete and tilt-up concrete elements. It explains: what the industry guidelines are for using precast and tilt-up concrete. how to train workers in health and safety identify hazards and when to notify WorkSafe about workplace injuries and deaths.
Learn More